Know the real health of your home’s wiring — down to every lug.
General home inspectors aren’t allowed to pull dead-front panel covers to check torque, load-test branch voltage drop, or open suspect junction boxes. Whether you are buying a 1960s Austin ranch, renewing homeowners insurance on a 30+ year old house, or welcoming a new baby home, a licensed DC Electric electrician inspects 75 critical points and hands you a clear written report.
Don't take our word for it.
From the utility weatherhead on your roof down to the receptacles behind your kids’ beds.
Electrical hazards rarely announce themselves before a failure — a loose 100A subpanel lug, a double-tapped neutral busbar, an ungrounded 3-prong outlet disguised with a bootleg jumper, or an open attic splice buried under blown-in cellulose insulation can sit silently until summer AC peak load arrives.
Our licensed electrician works systematically from outside in: examining your utility service mast, drip loop, meter base jaws, main breaker busbars, breaker brand & trip-failure history, neutral-to-ground bonding, grounding electrodes, whole-home surge protection, accessible attic wiring, kitchen/bath/exterior GFCI trip thresholds, and smoke/CO alarm expiration dates.
What’s Included With DC Electric
- High-failure & insurability-flagged panel screening: Federal Pacific (FPE) Stab-Lok, Zinsco, GTE-Sylvania, Challenger, and Pushmatic busbar inspection
- Branch conductor verification: distinguishing safe copper or modern AA-8000 feeder aluminum from 1965–1974 solid single-strand aluminum or brittle 1940s cloth-insulated ungrounded wire
- Receptacle polarity, open-ground, bootleg-ground, and mechanical tension testing across living areas, kitchens, baths, garages, and patios
- Smoke and carbon monoxide detector age check (every UL smoke sensor expires 10 years from manufacture date — even if the test button still chirps)
Every item ranked clearly: Immediate Safety Hazard, Code Modernization, or Healthy.
Homeowners hate feeling ambushed by vague electrical jargon. At the end of our evaluation, we walk you through photos of your own panel and wiring in plain English and separate genuine safety or insurance-blocking issues from "nice-to-have" modern conveniences.
If your home passes cleanly, you get peace of mind and written documentation from a licensed Texas Electrical Contractor (TECL #38552). If repairs are needed, we provide itemized flat-rate written options on the spot so you can tackle urgent items first and plan upgrades on your own timeline.
What’s Included With DC Electric
- Ideal for pre-listing sellers in Tarrytown, Hyde Park, Allandale, Travis Heights & Old Lakeway who want zero closing-week surprises
- Satisfies Texas insurance carrier requests asking a licensed electrician to verify panel brand, amperage, and wiring type on homes 25–40+ years old
- Includes NEC Article 220 capacity check if you are planning future EV chargers, induction appliances, solar, or a backyard pool/spa
- Any repair you choose is backed by our 5-year workmanship warranty (10-year workmanship warranty on panel replacements)
60-Second Electrical Emergency & Utility Outage Triage
Select what your home is doing right now. Get plain-English safety steps — including an honest check on whether your local electric utility fixes the problem at $0 utility cost before you hire an electrician.
Turn off that circuit breaker immediately — do not plug anything back in.
Electrical outlets, switches, and breaker housings are molded from heat-resistant thermoset plastics. When a loose wire lug, backstabbed receptacle, or failing breaker begins arcing, those polymers release a distinct acrid plastic or "dead fish" odor before visible smoke appears.
- If you see active smoke or flame, evacuate everyone (and pets) immediately and call 911 from outside.
- If there is no smoke, go to your breaker panel and switch OFF the breaker controlling that room or appliance. If the main panel itself smells hot or buzzes loudly, shut off the Main Breaker only if the panel cover is cool to the back of your hand.
- Never touch a scorched metal outlet screw or wet floor, and do not flip an overheating breaker back ON "just to test it."
Utility crews cannot repair interior outlets or branch breakers. A licensed electrician should open the box, cut back heat-damaged copper insulation, and torque a commercial-grade replacement.
Read full Burning/Fishy Smell Safety Guide →One of your two 120V power legs is out — check your utility before paying an electrician.
Every Austin home receives two 120V hot legs (240V total) from the utility transformer. When one leg drops, roughly half of your 120V lights/outlets go dark and 240V appliances (central AC, electric dryer, oven, EV charger) stop running—even though no breaker looks tripped.
- Turn OFF your central AC thermostat and unplug sensitive 240V equipment so a partial-voltage leg does not damage compressor windings.
- Call your electric utility outage line below FIRST and report "partial power / dropped leg." Over half the time in Central Texas storms or heatwaves, the loose lug is on the utility pole or pad transformer — and your utility repairs their side at $0 cost to you.
- If your utility tests the meter and confirms full 240V arriving at the meter base, the failure is customer-side (corroded meter jaws or a failed main breaker) — call DC Electric and we will take it from there.
We never want an Austin neighbor paying a service fee for a utility-owned pole splice. Always let Austin Energy, Oncor, PEC, Bluebonnet, or GUS verify their drop first.
Explore Customer-Side Main Breaker & Meter Repairs →Brightening lights signal a dangerous loose neutral — protect electronics today.
A brief 1-second dip when a 4-ton AC compressor starts can be normal inrush current (often cured with an AC soft-start). However, if lights in one room get noticeably BRIGHTER while lights elsewhere dim when a microwave, toaster, or hair dryer runs, your 120V legs are unbalanced due to a failing neutral connection.
- Unplug expensive electronics, OLED TVs, and countertop appliances on affected circuits — a floating neutral can send 145V–170V into a 120V outlet and fry control boards.
- If overhead tree limbs rub your backyard power drop (common in Tarrytown, Hyde Park, Barton Hills & Travis Heights), ask your utility to check their overhead neutral splice while scheduling an inspection of your main panel neutral bus.
- If flickering happens ONLY on one dimmer switch with LED bulbs, it is safe — usually an incompatible legacy dimmer rather than a loose neutral.
We test voltage under load at both the meter and main panel busbar so we pinpoint whether the loose neutral is inside your panel or out at the utility tap.
Read Austin Flickering Lights Diagnostic Guide →High-failure breakers and oxidized aluminum splices look normal until overloaded.
Homes built across Austin between 1950 and 1982 frequently still carry Federal Pacific Electric (FPE Stab-Lok) or Zinsco / Sylvania panels—documented for failing to trip during overloads—or 1965–1976 single-strand aluminum branch wiring that expands and loosens at brass outlet screws.
- Do not pry off the dead-front metal inner cover yourself, and avoid running space heaters or high-draw EV adapters on legacy FPE/Zinsco circuits.
- Look at the inside door label: red-tipped breakers or "Stab-Lok" indicate Federal Pacific; pastel blue/pink/green vertical handles indicate Zinsco.
- Schedule a pressure-free evaluation. We replace high-failure hazard panels in one coordinated day (backed by our 10-year panel warranty) and perform CPSC-recognized AlumiConn torque-verified remediation.
Replacing an FPE or Zinsco panel also resolves the #1 red flag on Texas homeowners insurance renewals and TREC real estate option-period inspections.
See Same-Day FPE & Zinsco Replacement Details →Your GFCI or AFCI is doing its job — trace moisture or hidden upstream resets.
After heavy Central Texas storms, wind-driven rain enters aging exterior bubble covers, holiday lighting cords, or pool/patio boxes. A single garage or bathroom GFCI receptacle often protects 4–8 downstream outlets across the house.
- Unplug every cord from outdoor patio, soffit, garage, and landscape outlets first.
- Check garage walls, bathrooms, laundry rooms, and exterior walls for a tripped TEST/RESET receptacle. Press RESET firmly with dry hands only after unplugging wet outdoor cords.
- If water is dripping INTO your main breaker panel or meter can, stand clear of wet concrete and call immediately — water inside a live busbar corrodes breaker jaws and can arc.
We upgrade leaky flat exterior flaps to NEC-compliant weather-resistant (WR) GFCI receptacles with heavy-duty weatherproof in-use covers.
Explore Weatherproof GFCI & Outlet Repairs →Count the beeps: 4 rapid beeps means Carbon Monoxide; 1 chirp means battery/age.
Hardwired 120V smoke and carbon monoxide alarms communicate interconnected alerts across every bedroom and hallway. Knowing the beep pattern tells you in seconds whether you have a life-safety emergency or an expired 10-year sensor.
- 4 rapid beeps, pause, 4 rapid beeps: Active Carbon Monoxide (CO) alarm. Move everyone outside to fresh air immediately and call 911 — CO is odorless and invisible.
- 3 loud beeps, pause, 3 loud beeps: Smoke/fire alarm trigger (or heavy steam/attic dust inside an aging sensing chamber). Verify no fire or hot electrical smell first.
- 1 single chirp every 30–60 seconds: Low backup battery OR end-of-life timer. NFPA 72 requires replacing every smoke/CO unit every 10 years because sensors lose sensitivity.
We replace aging chirping alarms house-wide in one visit with interconnected 120V photoelectric smoke + CO units carrying sealed 10-year lithium backups.
See Whole-Home 10-Year Smoke & CO Replacement →Recent residential work completed near Greater Austin
Anonymized completed job records synced from our ServiceTitan dispatch log (429+ Greater Austin residential projects completed over the last 6 months, including 429 in Greater Austin). Customer names and street addresses are omitted for homeowner privacy.
200-Amp Panel & Austin Energy Meter Base Upgrade
Dedicated Circuit, GFCI/AFCI Protection & Smart Switch Install
Dedicated 240V Hot Tub, Spa / Sauna & GFCI Disconnect Wiring
Answers about 75-point electrical safety inspection in Austin
How is an electrician’s 75-point inspection different from a standard home buyer inspection?
My Texas homeowners insurance company asked for an electrical inspection letter — can you provide that?
How long does a 75-point home electrical safety inspection take?
Will power need to be turned off during the inspection?
Connected electrical work across Greater Austin
We treat every home like our own. Here’s what neighbors say about DC Electric.
Being invited into your home is a privilege we never take for granted. Every story below comes straight from a Greater Austin homeowner we’ve served — with the work we did and the DC Electric crew who showed up.
“The DC Electric team was phenomenal! They came out and replaced a tricky inset panel in one day. Rodney, Anthony, Andrew, Rico were professional, quick, and filled us with confidence that they could get the job done. They worked with Austin Energy to get permits approved and finish the inspection in record time. We are beyond impressed with their excellent work! This was no easy job.”
“Nick came out for the quote — kind and thorough, and helped me think through all the work. Install day was flawless: the crew put in a car charger, 16 can lights, and two new circuits, and insisted on making it perfect. They are not the cheapest electricians in town, but you absolutely get what you pay for.”
“I purchased a 1951 home with multiple electrical issues on the inspection. Every deficiency was addressed — and they told me which components did not need updating. A storm rolled in while I was away and the techs closed all my windows. I came home to a dry house.”
“I needed to replace my panel, and add outlets to the bathroom and garage. Pete was helpful in getting my estimate. Max and Rico did a great job with the installation. Everyone was very friendly. The pricing was straightforward and fair. They had me scheduled fairly quickly and finished the job quickly.”
“They showed up right on time and worked nonstop in the heat, provided a generator so we had power while they worked, answered every question, explained everything, and cleaned up before leaving. I’ll definitely use them again.”
“Big thank you to Rodney, Max and Pete from DC Electric who helped us install new recessed lights in our kitchen. They were on time, super helpful working out what would work best, did a good quality install and clean up and were very friendly and easy to work with. Will definitely use again!”
“We got multiple bids to restore power to our garage unit, and the team at DC were the easy choice. Scheduling was easy, communication was consistent, and most importantly, they took care of everything thoroughly — complete on time, with no surprises.”
“Fast, efficient, clean, and extremely knowledgeable about the hardware and setup. Ed and the crew walked me through the whole system and I’ve spent hours playing with my new SPAN setup!”
“Andrew and Jonathan did an amazing job installing our EV charger. They walked us through the setup, stayed true to the quote, and left the garage cleaner than they found it.”
“Rico, Rodney and Nathan were professionals with my charger install. Explained every step of the process to me, informed me of every step during the install, and walked me through final install and operation. Left a clean work space, and their final work looked very clean. Highly recommend!”
75-Point Electrical Safety Inspection in Austin, priced clearly before work begins.
Book online 24/7 or call 512.954.4782. A licensed DC Electric electrician evaluates your home in person, walks through options in plain English, and gives you one exact flat-rate written price.